Search results for "2741 Radiology"
showing 10 items of 11 documents
Reduced interhemispheric structural connectivity between anterior cingulate cortices in borderline personality disorder
2008
Functional and structural alterations of the anterior cingulate cortex (ACC), a key region for emotional and cognitive processing, are associated with borderline personality disorder (BPD). However, the interhemispheric structural connectivity between the left and right ACC and between other prefrontal regions in this condition is unknown. We acquired diffusion-tensor imaging data from 20 healthy women and 19 women with BPD and comorbid attention-deficit hyperactivity disorder (ADHD). Interhemispheric structural connectivity between both sides of the ACC, dorsolateral prefrontal cortices and medial orbitofrontal cortices was assessed by a novel probabilistic diffusion tensor-based fiber tra…
Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms
2011
Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…
Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery
2014
Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…
On the consensus nomenclature rules for radiopharmaceutical chemistry – Reconsideration of radiochemical conversion
2021
Radiochemical conversion is an important term to be included in the "Consensus nomenclature rules for radiopharmaceutical chemistry". Radiochemical conversion should be used to define reaction efficiency by measuring the transformation of components in a crude reaction mixture at a given time, whereas radiochemical yield is better suited to define the efficiency of an entire reaction process including, for example, separation, isolation, filtration, and formulation. (C) 2020 Elsevier Inc. All rights reserved.
Chimney and periscope grafts observed over 2 years after their use to revascularize 169 renovisceral branches in 77 patients with complex aortic aneu…
2013
^ ^Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in theendovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelfdevices.Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; meanage 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch tovisceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiringchimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned inadvance and were not used as bailout. A standardized follow-up protocol includingcomputed tomographic angiography, laboratory testing, and clinical examination wasp…
Radiomics and artificial intelligence in prostate cancer: new tools for molecular hybrid imaging and theragnostics
2022
AbstractIn prostate cancer (PCa), the use of new radiopharmaceuticals has improved the accuracy of diagnosis and staging, refined surveillance strategies, and introduced specific and personalized radioreceptor therapies. Nuclear medicine, therefore, holds great promise for improving the quality of life of PCa patients, through managing and processing a vast amount of molecular imaging data and beyond, using a multi-omics approach and improving patients’ risk-stratification for tailored medicine. Artificial intelligence (AI) and radiomics may allow clinicians to improve the overall efficiency and accuracy of using these “big data” in both the diagnostic and theragnostic field: from technical…
Predilation technique with balloon angioplasty to facilitate percutaneous groin access of large size sheath through scar tissue
2017
Purpose Percutaneous remote access for endovascular aortic repair is an advantageous alternative to open access. Previous surgery in the femoral region and the presence of synthetic vascular grafts in the femoral/iliac arteries represent major limitations to percutaneous remote access. The aim of this study was to evaluate an original technique used for enabling percutaneous remote access for thoracic or abdominal endovascular aortic repair in patients with scar tissue and/or a vascular graft in the groin. Methods Twenty-five consecutive patients with a thoracic (11/25; 44%) or an aortic aneurysm (14/25; 66%) and with a synthetic vascular graft in the groin (16/25; 64%) or a redo groin acce…
A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be cl…
2012
Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …
CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies
2013
PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…
Endoluminal Stent-Graft Relining of Visceral Artery Bypass Grafts to Treat Perigraft Seroma
2013
PURPOSE: To describe the endovascular treatment of intra-abdominal perigraft seromas associated with small-caliber expanded polytetrafluoroethylene (ePTFE) grafts. CASE REPORTS: Two patients who underwent hybrid repair of thoracoabdominal aortic aneurysms in which renovisceral bypass grafts were implanted presented with large, symptomatic perigraft seromas. The 5- to 8-mm-diameter ePTFE bypass grafts believed to be involved in the seromas were successfully relined with self-expanding Viabahn stent-grafts in percutaneous procedures. The patients' symptoms were relieved, and imaging follow-up (18 and 10 months, respectively) has shown near complete resorption of the seromas. CONCLUSION: It is…